Please enable Javascript for better experience...
NSX for Vsphere 6.4 ICM
By Jitendra | May 8, 2019 | In Articles | Update: Apr 27, 2020 | Total Views [ 1052 ]
Taged In
(0 Like)
Rate

ntial description

NSX Manager 6.4 (NSX-V)

NSX Manager is widely adopted as network virtualization in the Vmware environment.

In the later days of the NSX-V, VMware has announced the NSX-T where it supports multi hypervisor environment along with cloud. It is developed with open source and installed in KVM.

V stands for Vsphere and T stands for 'Transformers'.

Architecture:

It is defined in three module architecture Data, Control & Management plane.

Data Plane: NSX logical switch, Hypervisor Kernel module where install scripts & configuration files are held and managed.

Control Plane: NSX controllers that basically state management system which makes the function enabled for the logical switching and routing.

 

Management Plane: NSX manager is the core component of it as it holds all the management. It also enables the REST API entry.

Hardware Requirement:

Component                                        Memory                             CPU                       Hard Disk

NSX Manager                                    16 GB                                    4                              60GB

NSX Manager (Large Infra)          24 GB                                    8                              60 GB

NSX Controller                                  4 GB                                       4                              28 GB

NSX Edge                                             Compact: 512 MB              Compact: 1           Compact: 1 disk 584MB + 1 disk 512MB

                                                           Large: 1 GB                      Large: 2                Large: 1 disk 584MB + 1 disk 512MB

   Quad Large: 2 GB                  Quad Large: 4       Quad Large: 1 disk 584MB + 1 disk 512MB

 X-Large: 8 GB                         X-Large: 6            X-Large: 1 disk 584MB + 1 disk 2GB + 1 disk 256MB

Guest Introspection                            2 GB                                       2                              6.26 GB

Software Requirement:

Vsphere 6.0 Update 2 & 3

Vsphere 6.5a and update 2

Vsphere 6.7 & Update 1

 vSphere 5.5 is not supported with NSX 6.4


text